Heatstars training courses are free of charge and offer genuine practical benefits and certified career enhancing skills development. The air pump rotor disintegrated, so I replaced it. Replace. Either lack of fuel or too much fuel can be fixed fast with a bit of testing Thanks for watching ! Service plans Gold Silver Bronze Servicing Routinely serviced twice per year to ensure the Heatstar is working efficiently and safely Parts 2023 Mi-T-M Corporation | 50 Mi-T-M Dr., Peosta, IA 52068 | 1-800-553-9053 To fix a faulty thermocouple, you can first attempt to clean the old one, and you can do this by wiping away dirt and debris or sanding off corroded metal. Could you let us know what the model number is on the heater? Purchased in spring of 2019 as had JD 190 that functioned perfectly 2015 to this day. Should You Put A Ceiling Fan In Your Bedroom Yes Or No? Recheck the rotor installation, the 4 small vanes may be installed incorrectly. JET TUBE HEATERS File Downloads 2019 JET Radiant Tube 80k-100k BTU Heater System Manual 2021 JET Radiant Tube 80k-100k BTU Heater System Schematic (Size: 9.7 MB) COMFORTER TUBE HEATER SYSTEMS File Downloads Product Description Permanently seals leaks in: Condenser, Evaporator, Accumulator, Compressor, Gaskets, O-Rings, Metal & Rubber Hoses. The gas valve may be faulty and has to be replaced. Replace. The tube is super small, making a needle the only object thin enough to fit inside. I can take the cover off start and then screw the cover on, and it will run all day with no issues. 1 Power Cord Assembly Part Number:21036 In Stock, 2 available $7.06 Add to Cart 2 Fuel Tank Assembly Obsolete - Not Available Part Number:22214 Discontinued 3 Radiation Shield Assembly Part Number:21783 In Stock, 1 available $82.91 Add to Cart 4 Power Pack Assembly Part Number:26975 Ships in 5 - 10 business days $272.46 Add to Cart 5 Fuel Tube Pilot lights but goes out Defective thermocouple. If your gas wall heater keeps shutting off, dont get frustrated. Let us know if you have any further questions & feel free to give us a call at 1-800-553-9053. Then reassemble the gas heater and turn on the gas. If the thermocouple is faulty or damaged, it may have stopped sending signals, and the pilot light is unable to stay lite, causing your wall heater to stop working. I noticed some fuel leaking out the front of the burner so tipped it to drain the puddle inside and now Im letting it sit for a cpl hours to dry out. Check for a hole(s) in the air hose that connects the air pump to the burner nozzle. WHERE TO BUYWARRANTY REGISTRATION CONTACT US BECOME A SERVICE CENTER WEBSITE FAQs. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'homedecorselection_com-leader-1','ezslot_8',160,'0','0'])};__ez_fad_position('div-gpt-ad-homedecorselection_com-leader-1-0'); If your trouble isnt with the pilot lite, the problem could have something to do with the Thermostat, gas valve, or even the transformer. Compact Unit Heater E-5 Fuel Conversion Manual I have a Master MH-75T-KFA, a 75KBTU heater that looks exactly like the one above (except no display on circuit board) Fuel filter 2. Other times, there may not be enough oxygen in the area, causing the flame to suffocate and keeping it from staying lite. The 215 would sometimes start and then others not and did not heat as the 190 does and would shut down with an E1. My heater lights sometimes on the second or third try. Saved me from unnecessarily replacing the igniter. I do not assume any responsibility for anything shown or mentioned on this channel. Below are all the ways you can contact us and how to access the resources weve tried to provide on the site. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'homedecorselection_com-large-leaderboard-2','ezslot_2',157,'0','0'])};__ez_fad_position('div-gpt-ad-homedecorselection_com-large-leaderboard-2-0'); In this situation, the only way to correct the problem is by controlling the air circulation in the area. You can try to contact them here http://www.protemp-intl.com/index.php. Our team prides itself on finding you a solution. We have created a list of the top problems people seem to have with their home gas wall heaters and found ways the experts suggest using them to solve them. This is a genuine manufacturer supplied replacement rotor kit specially designed for use with Heatstar and Mr. Heater heaters. Possible Cause #1 If you are trying to light your KFA Portable Heater and you notice little or no air pressure registering on the pressure gauge, there may be an issue with one of the following components: 1. Burner flashback (roaring noise during operation supplier and ceramic grid surface will be dark) Low gas pressure. If that doesnt work, unscrew one end of the thermocouple from the gas valve, remove the other end from the pilot light bracket, and replace a new thermocouple onto each end. The wiring should be connected to the motor. The voltmeter should read 120 volts AC. In Stock. Whyht7rCka /?T G.37. By investing in Heatstars technical training, held in AstralPool UKs dedicated training facility, you will develop the specialist knowledge and practical skills that will enable you to install and maintain Heatstar systems as well as advancing your industry qualifications. If this is the case, there are a couple of things you should consider. The fuel gauge lights you are describing seem a little unfamiliar, or feel free to give us a call at 1-800-553-9053 and wed be happy to help you trouble-shoot it. Retired. The store will not work correctly in the case when cookies are disabled. 85% more efficient Find out more Trusted expertise since 1980 For over 40 years Heatstar have been setting the benchmark in an environmentally conscious industry Nationwide support Hi, I have a brand new Heatstar 210. Hello Mark, If there is a blockage in the pilot tube or the pilot tube is dirty, this will affect the performance of the pilot light causing it to turn off at random times. Color stays dull. This item: Heatstar By Enerco F125444 Radiant Overhead Garage Heater MH25NG Natural Gas $477.39 Mr. Heater One-Stop Universal Gas-Appliance Hook-Up Kit,Small $24.40 Mr. Heater Thermostat for Heater,Tan,Small $19.96 natural gas warehouse heater mr heater wall mount infrared natural gas heater mr heater f272800 mr heater shop heater Click here to submit an inquiry for dealers or distributors in your area via our form. Remember, never do any type of work with gas lines and pilot lights unless you are taking safety measures and fully understand what you are doing. Fixing the wiring should solve the problem. If you are trying to keep a room warm, but the hot air keeps leaking through the walls or windows and doors, your issue is due to the insulation, not the wall heater. LhedAV!*WB EqPYH JCZbMMZ (1[6&8pCY[t7>I@8a>d-]&"XRq4W#E}zY}eM2.G`$\ [
How Does a Gas Wall Heater Work and How to Fix it? A thermocouple is a tiny safety device that controls the flow of gas released to your pilot light on your gas heating system. This article is a quick guide to helping wall-mounted gas heater owners troubleshoot common problems and quickly fix them themselves. Failure to ignite Main gas off. After the pilot lights, continue holding the knob for around 30 seconds. Also, vacuum the debris from the vent holes and inside the grid of the heater. Hi Dave, the rotor needs to be adjusted to .003 clearance. First, make sure the pilot is out, then turn the temperature all the way down on the thermostat. Igniter (which ismounted underneath the fan pictured below). Turn off the gas. Place instructions in a safe place for, future reference. There are times where all you need to do is re-set your gas wall heater if it isnt working as it should. 2N^o\XE@K%GvVThH.3 Pump pressure is set at 6.8 according to the specs. Also check for obstructions. Replace the air hose or air pump rotor based on the root of the cause. Pump fan works and is set for 5.1psi of pressure. However, maintenance is still key to having a top-notch, optimal-performing gas heater. Amazon and the Amazon logo are trademarks of Amazon.com, Inc or its affiliates. Loose wire or improperly wired Tighten connections and check wiring. I have a JD ac 215 for about 2 years very hard to start says E1 tried it yesterday could not get it to start ,took hood off and fan has hard spots turned it by hand (it was unpluged) when turned back on it did finaly started .Today the same thing has not had over 5 gal of kero since new.could it be air pump rotor clearance. Replace. Heatstar believe that after sales support is so vital that it is something that can never be left to chance or, for that matter, in the hands of any third party. If the proper air pressure is registering on the pressure gauge (see heater decal for proper pressure) and the heater sprays fuel, but you still cannot light up your KFA Portable Heater, there may be an issue with one of the following components: 2. Part Number: F226831. If you think there is something wrong with your thermostat, you may want to check the batteries; if they are okay, try re-setting it through the factory reset option. Page 14: Maintenance Frequency 10.1.3. Routinely serviced twice per year to ensure the Heatstar is working efficiently and safely, In the event of a breakdown there is no charge for parts, In the event of a breakdown there is no charge for labour, In the event of a breakdown there is no charge for attendance. The store will not work correctly in the case when cookies are disabled. Sometimes pilot lights can be affected by drafts or a breeze flowing through the basement or room the system is set up in. Step 1 Inspect the power cord if the motor won't start. You should never attempt to repair a gas valve by yourself. SWITCH-OFF: heater to cool. Hope that helps! Im guessing its the board, but wondering if anyone else has seen this? Do ceiling fans really help in the winter? endstream
endobj
224 0 obj
<>stream
The other likely cause is a problem with the control switch or the thermostat. So I finally got around to take it apart and found that it was the air pump rotor binding up causing not to start. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. DO NOT OPERATE HEATER WHERE FLAMMABLE LIQ- UIDS OR VAPORS MAY BE PRESENT. Replace. Easily installed in minutes Professional strength formulation Blow compressed air into the tube to remove debris. Phones can turn off as early as 3:00 pm EST the business day prior to the holiday. The first will be when the flow of air to the unit is blocked, by drapes or something similar. If you need technical support or help with obtaining a part number, you need to first contact Mr. Heater / HeatStar at the numbers above. This will give the thermocouple enough time to heat up. CONSUMER CONTACTS: For inquiries regarding, HeatStar and HeatStar AG products, please call: Toll Free 1-866-447-2194 (USA & Canada) Heatstars permanently installed products are also found in commercial and industrial applications across the United States and Canada. You can contact Jeff Riesberg or another member of our service team a 1-800-553-9053. Im running furnace oil in it and set the temp to around 50F. Defective control. We are proud to feature brands like HeatStar in our online catalog of construction tools and equipment. HL Troubleshooting Flow Chart (models with no Relay Board) NO Is there 120V on the primary side of the transformer? Please call beforehand to make sure they can handle your request. Please contact our Product Support Team at 800-553-9053 if youd like us to walk you through it. It may continue to run or may go out after ten seconds or so, relight and repeat this process a couple of times. I purchased the JD ac 215 January 30, 2020 for outdoor use. Make sure the unit is plugged in, and that the voltage at the outlet matches the required voltage listed on the heater instruction plate found on your unit. Heatstar Brand features portable heating products designed and engineered for the professional market which includes construction sites and rental dealers. Same problem with a JD 215 heater as above. You can do this using a needle and pushing it into the line. Master MH-140T-kFA does not want to fire below about 32 degrees, and when it does its spitting fuel out while its on. If you have any questions in the meantime, please feel free to give us a call at 1-800-553-9053. PLUG ELECTRICAL CORD INTO A PROPERLY GROUND- ED THREE-PRONG RECEPTACLE. The cause of a weak, flickering pilot light can be due to too much or too little oxygen. Defective control. If the gas valve isnt working correctly or locks up, then the wall heater could shut down, and the appliance wont turn on. Home Decor Selection is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. There are many simple solutions to try before it becomes a serious or expensive situation. Tighten the bolts in the steel ring. Pilot stays lit but main burner will not light. It is a heat. With a team of their own dedicated engineers located throughout the UK, Heatstar are able to deliver an unrivalled level of after sales, preventative maintenance and response support service. Shows E-4 on error code. direct fired heater (28 pages), Plaque heaters, blue flame heaters (16 pages), Forced-air propane construction heater (24 pages), Compact unit heater for residential/commercial use (68 pages), High intensity infrared heater (32 pages), Manual will be automatically added to "My Manuals", Operating instructions and owner's manual, Heater HeatStar HS125NG Operating Instructions And Owner's Manual, Heater HeatStar HS115TC Operating Instructions And Owner's Manual, Heater HeatStar HS100CVNG Operating Instructions And Owner's Manual, Heater HeatStar HS115SF Operating Instructions And Owner's Manual, Heater HeatStar HS18CH Operating Instructions And Owner's Manual, Heater HeatStar HS50K Operating Instructions And Owner's Manual, Heater HeatStar HS4030 Operating Instructions And Owner's Manual, Heater HeatStar enerradiant HST35 Operating Instructions And Owner's Manual, Heater HeatStar HS 3500DF Operating Instructions And Owner's Manual, Heater HeatStar HS55FAV Operating Instructions And Owner's Manual, Heater HeatStar HS4000 NG/LP Operating Instructions And Owner's Manual, Heater HeatStar HSSVFRD10LPT Operating Instructions And Owner's Manual, Heater HeatStar HS400FAVT Operating Instructions And Owner's Manual, Heater HeatStar HS250AG Operating Instructions And Owner's Manual, Heater HeatStar HSU50 Operating Instructions And Owner's Manual, Heater HeatStar HSRR30SP(LP) Operating Instructions And Owner's Manual. Burner light off very slow Partially blocked pilot orifice. Step 1: Turn Off the Gas Supply. Hi Steven, [Heres What To Do]. portable construction heater (18 pages), Convection Link above is for a torpedo heater that won't light because of lack of fuel. I have a duroheat kfa heater I plugged into a 220 v plugin with a rv plug that make 220v to a 110v connection and heater turned on and ran for about 5 seconds then turned off and now it does not turn on at all I checked fuse on board and it looks fine to me what else can I check or did I fry the board completely? EPA certified residential refr. Getting 119VAC at cord thats plugged into the heater. Whats my next step? If you do happen to have to replace your gas wall heater and want to change to electric, read our guide on the best electric wall heaters. I have a DXH185KT that I am struggling to diagnose. Repair or replace a damaged cord immediately. For the best experience on our site, be sure to turn on Javascript in your browser. Although, this is a pretty uncommon problem these days, with all the safety features in place. If the wiring is bad or loose, it will not send the correct signals and will not heat up. it has a unique power pile thermocouple to control the valve, there is no No kerosene is being sent to the glow plug which is lighting. Heatstar offer planned maintenance agreements on all of their products to ensure that the Heatstar system continues to operate to its optimum performance. If your propane heater has a standing pilot, you should be able to see it through a small window or opening near the control knob. Click here to find a service center near you. Air in gas line. Burner light off very slowly. Learn more. Replacing your entire furnace and wall heater system can get very expensive and will be a long and rough process. Video - Troubleshooting Basic Methodologies 3 Common Causes for Connecting to Linkus Softphone Server Error; Get correct logs & submit tickets for Yeastar troubleshooting (including Wireshark,Notepad++,Putty) Analyze PBX System Log by Notepad++ (SIP Event/Extension Registration Failure/Outbound Call Failure) Correct line pressure or call your gas. Heater shows 0/1 red light on fuel gauge but has 1/2 tank of fuel no response after supplying power. Is there 24V on secondary side of transformer? Add to cart. construction heater (20 pages), Plaque heaters, blue flame heaters (16 pages), Forced-air propane construction heater (24 pages), Compact unit heater for residential/commercial use (68 pages), Manual will be automatically added to "My Manuals", Heater HeatStar HSP400ID-G Operating Instructions And Owner's Manual, Heater HeatStar HSP60R Operating Instructions And Owner's Manual, Heater HeatStar HSP70ID Operating Instructions And Owner's Manual, Heater HeatStar HS50K Operating Instructions And Owner's Manual, Heater HeatStar HS4030 Operating Instructions And Owner's Manual, Heater HeatStar enerradiant HST35 Operating Instructions And Owner's Manual, Heater HeatStar HS 3500DF Operating Instructions And Owner's Manual, Heater HeatStar HS55FAV Operating Instructions And Owner's Manual, Heater HeatStar HS4000 NG/LP Operating Instructions And Owner's Manual, Heater HeatStar HS125NG Operating Instructions And Owner's Manual, Heater HeatStar HS115IR Operating Instructions And Owner's Manual, Heater HeatStar HSSVFRD10LPT Operating Instructions And Owner's Manual, Heater HeatStar HS400FAVT Operating Instructions And Owner's Manual, Heater HeatStar HS115TC Operating Instructions And Owner's Manual, Heater HeatStar HS250AG Operating Instructions And Owner's Manual, Heater HeatStar HSU50 Operating Instructions And Owner's Manual, Page 18: Instructions Pour L'installation. The technology relating to the heating and ventilation of modern swimming pools is fast-moving, highly legislated and environmentally challenging. To fix a faulty thermocouple, you can first attempt to clean the old one, and you can do this by wiping away dirt and debris or sanding off corroded metal. ! To do this have the rotor in place and the outer steel ring loose, then place the .004 inch gauge between the top of the rotor and the bottom of the outer ring. I have a Dyna-Glow Delux Professional 180k-220k BTU heater. If the fan is obstructed, it will not spin. If it only falls to 7.0, it will continue working but poorly. Adequate combustion and ventilation air must be provided. Replace if damaged. Step 12 Disconnect the manometer from appliance and replace the test plug on valve removed in step 6. If your pilot light is flickering or too weak, it may not be able to keep your gas heater running correctly. no?M4\,3ORxdQAmcf~~D)_1`;[ ^Ya)Y-c4#c#j "mHH%iA# d lh[r$*0D,kjt&,uhof
H\S+{Yazo)Gwmtd($MvPSy18G=2A i8 DDFzw0c|)a)jg*vc+qJR)#b'
qa-H(5FO!`VQXg] 2cgYL*;\g^pOI{~`M#JgO]$Sxas\@Xz7B%G}OG^dkc.$Yi+Xoy/TY4#r8~? I have a readyheater pro 155.has been completely serviced,filters air fuel,spark plug new and gapped,air psi set to 5.2 psi,checked for air leaks,new hoese air fuel,tested ign ok, new nozzel.will not fire hot (60 deg),fires cold fine(30 deg).will fire with torch held near spark plug and run fine.any ideas? Either lack of fuel or too much fuel can be fixed fast with a bit of testing It's cable reimagined No DVR space limits.. Copyright 2020 - 2022 | All rights reserved. I thought when I was getting below 110 out of the connector with the blue wires that it was the problem, but no way to know for sure. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. For all mobile air conditioning systems R134A and R12/R22 An essential part of reconditioning used vehicles. Alternatively, the pilot light may not stay lit after initially being triggered. Below are all the ways you can contact us and how to access the resources we've tried to provide on the site. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. If you'd like to see what's happening in upcoming videos check out my instagram page. When it does go out the combustion air blower continues to run as well as the fan and the heater will try and restart the flame. Learn more. Ideal for apprentices, engineers, and trade installers alike. Ceiling Fan Not Working On All Speeds? WELCOME TO HEATSTAR SUPPORT Our team prides itself on finding you a solution. endstream
endobj
225 0 obj
<>stream
Here are a few options to look into if your gas wall heater. The pilot tube is a tiny thin tube that keeps fuel pushing through to the pilot flame, keeping the flame burning. Please contact Technical Support at 800-367-6486, they should be able to help you out. The store will not work correctly in the case when cookies are disabled. x!V
To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. I have no spark, have replaced spark plug, that did nothing, and when I remove wires from circuit board to check output to igniter, I get 82VAC. If you still can't get the heater working again, it probably needs a new heating . After starting it and setting the temp, it seems to work fine. Remove the heater control knob, thermostat knob and faceplate to check for loose connections in these mechanisms. For the Mi-T-M Pressure Washer Certified Technician. If setup for Propane, the inlet gas pressure switch my be open. [How To Fix It]. Clean orifice or replace. We partner with many independent service centers around the United States. If burner orifice is not damaged then check for damaged manifold. Gas Wall Heater Turns on But the House Doesnt Heat Up, Are Your Ceiling Fan Blades Drooping Or Warped? It uses air (oxygen) from the area in which it is used. Fuel fired portable radiant
If the heater turns on but the doesnt heat up, it probably has something to do with the heating element wiring. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. A thermostat is a communication between the room temperature and the gas valve. Replace. But after a few hours it shuts down and wont start. Replace. DO NOT PLACE COOKING UTENSILS ON TOP OF THE HEATER. Just like a bad thermostat will keep a gas wall heater from turning on, it can also keep them from shutting off. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! I replaced the control board and it fired right up. I followed all instructions to the letter but still wont start. YES NO Transformer is faulty and must be replaced. Thank you for joining our family of customers! If you do not find any holes, remove and inspect the air pump rotor for cracks and damage. Enerco HeatStar HS6000DF Forced High Pressure Direct-Fired Heater with 610000 BTU per hour is great for Construction sites Outdoor job sites Concrete freeze protection Crop drying Ventilated buildings Pilot cannot be ignited Blocked pilot orifice. Can anyone suggest a solution? My Mastercraft 115K btu heater will not fire. TROUBLESHOOTING GUIDE MODELS: DTH(S) Series Tube Heaterer Detroit Radiant Products Company 21400 Hoover Road Warren Michigan 48089 (586) 756-0950 Fax: (586) 756-2626 website: www.reverberray.com email: engineering@detroitradiant.com THESE HEATERS MUST BE INSTALLED AND SERVICED BY TRAINED GAS Then disconnect main electrical power, and turn the main gas supply off to appliance. Tighten any loose wires. I have a heat star HSP 500 it will not heat. Now, is this circuit board failure, or should I still be looking at igniter? First, make sure that you have. CLEANING THE FAN: and do not reuse them. Video of the Day Step 2 Turn off the unit and unplug it. Pilot out of adjustment. Manufacturer Part Number F226831. Air hose 3. When replacing the air pump rotor, you must set the proper gap at the top of the carbon rotor. This is one fix that doesnt require shutting off the gas and any power to the wall heater. For inquiries regarding, Mr. Heater, Cleveland Iron Works, Sunrite, and BaseCamp products, please call: Phone 1-800-251-0001 (USA & Canada) Fax 800-321-0552 or 216-916-3012. Insufficient Gas Another culprit for not a large enough flame is insufficient gas. For the best experience on our site, be sure to turn on Javascript in your browser. Any help would be greatly appreciated! Make sure the thermostat is set to the correct setting and that there's plenty of clearance for airflow around the unit. We use cookies to make your experience better. Gas Patio Heater Troubleshooting Burner light off very slow It fits inside the cylinder assembly and it is what moves the air. If the tube is blocked, clearing it out is pretty simple. Portable industrial natural gas/propane indirect heater (22 pages), Portable industrial oil-fired radiant heaters (18 pages), Portable industrial oil-fired indirect heaters (20 pages), High-intensity infrared heaters (48 pages), Gas-fired, low-intensity infrared heaters approved for residential garage/commercial applications (24 pages), Forced air propane construction heater (32 pages), Natural gas/lpg fired
Our Technical and Customer Service teams try to respond to all inquiries within one business day. Hours: Mon-Fri 8:00AM-5:00PM | Sat-Sun Closed, WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov. Most propane heater problems can be traced to a malfunctioning pilot. It seems odd to me that it isnt either 0V or 110V, but in the middle. Blocked burner orifice. Pilot gas flow adjustment screw may be closed Gas control knob must be turned to pilot and held depressed. Air pump rotor Solution: - Check to make sure the air pump filters and fuel filter are clean. E1 error. Its probably best to have you get some advice from one of our service techs. Hi Frank, Check to make sure the fuel filter and nozzle arent plugged. Trane B144676P01 Hot Surface 41-410 HSI Igniter Trane B144676P01 Hot Surface 41-410 HSI Igniter SKU: IGN1410 Availability: Usually ships within 24 hours Quantity Product Description Brand New, Unused- Replacement Hot Surface Ignitor Ceramic base that measures 1 1/4" wide x 1/2" thick Wire leads measure 5 1/2" long, with connector Ceramic grid or burner soot (when new or after cleaning) First check for damaged burner orifice. Now I do! Dirty wire connections. $ 49.46. Gas-fired infra-red
Although this is a great way to heat your home, it can be a little difficult to troubleshoot a problem when one arises. We use cookies to make your experience better. Next, turn the circuit breaker off that provides power to the wall heater and cut off the main gas supply going to the furnace, leaving the line to the pilot lite still active.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'homedecorselection_com-large-mobile-banner-2','ezslot_10',161,'0','0'])};__ez_fad_position('div-gpt-ad-homedecorselection_com-large-mobile-banner-2-0'); Finally, you need to relight the pilot light, turn the circuit breaker back on, and open the main gas supply to the furnace. Please give us a call at 1-800-553-9053 and wed be happy to help. It sounds like a bad board, if you want to test the igniter you can simply hook it up to 110 volts and see if it sparks. Heatstar 75,000 to 125,000 BTU Propane Forced Air Heater 3,000 Sq Ft Max Heating Area, 40 Lb Fuel Capacity Write the first review MSC Part #: 93178754 Mfr Part #: F170125 More Product Info in Catalog Price: $728.55 ea.